UPS systems
A UPS is not an expense — it is an investment in the safety of your data and the continuity of your business.
We supply professional UPS systems with the best batteries on the market. We specialise in on-line double-conversion units classified VFI-SS-111 — the highest protection category under IEC 62040-3, in which the load is isolated from mains disturbances and the transfer time is zero.
25+ years
of experience in uninterruptible power
~4000
completed installations
ISO 9001:2015
certified quality management system
A complete range from 1 kVA to 1200 kVA
From compact single-phase Tower and rack-mount units to modular 1.2 MW systems. One supplier, one service team, full system compatibility — the range covers both transformerless units and transformer-based units for harsh environmental and load conditions.
Single-phase Tower
1–3 kVA/kWCompact protection for individual workstations and critical devices.
Single-phase Rack/Tower
1–10 kVAMounts in a 19" rack or stands alone — the same unit in either position.
Single-phase Rack/Tower Li-Ion
1–3 kVAInternal lithium-ion battery: lower weight and longer service life.
Configurable Rack/Tower
10–40 kVAConfigurable phase arrangement 1/1, 3/1 and 3/3 — one unit for different supplies.
Configurable monobloc Tower
10–40 kVACompact free-standing enclosure for server rooms and plant rooms.
Monobloc
60–200 kVAPowers entire critical-load switchboards from a single cabinet.
Modular
30–1200 kVACapacity grows module by module, with N+1 redundancy and module replacement without dropping the load.
Builds from our range
The same ON-LINE technology in several formats — from a Rack/Tower unit for a single server cabinet to free-standing cabinets and lithium-ion batteries in a separate enclosure.
Efficiency that shows up on the bill
All our UPS units have an output power factor of 1, so every kVA of rated power is fully usable — 100 kVA means a real 100 kW for the load, with no headroom lost to phase displacement.
1.0
output power factor
up to 97%
efficiency in online mode (three-phase)
up to 99%
efficiency in ECO mode
up to 0.99
input power factor
Four percentage points is a concrete sum
On a 100 kVA unit, a difference of four percentage points in efficiency means 4 kW less loss. In continuous operation that is roughly 35,000 kWh a year — energy that would otherwise turn into heat the room has to get rid of instead of reaching the load.
Calculated for continuous operation at full load (4 kW × 8760 h = 35,040 kWh). At lower loads the saving is proportionally smaller, but it grows by the cooling cost you no longer have to carry.
W-ECO mode reaches up to 98% efficiency, combining the savings of ECO mode with a faster return to online operation when mains quality deteriorates.
What sets our UPS units apart
Electronics and control
- Dual DSP — a twin control and error-correction system.
- Latest-generation IGBT transistors and three-level topology: low harmonics and high efficiency.
- Full conformal coating on every PCB, protecting the electronics from the environment and corrosion.
- Fault tracking management (FTM) — records the causes of events, not just their effects.
- Intelligent battery charging that matches current to battery state and temperature.
Operation and reliability
- High inverter overload capability — headroom for load start-ups.
- Cold start: the UPS can be started from the batteries when there is no mains supply.
- Power walk-in — the mains and the generator are re-loaded gradually after supply returns.
- Intelligent generator mode, adapting UPS operation to work with a generator set.
- Parallel operation of 2–8 units with a common battery bank.
- Full rated power without derating up to 40 °C.
Operation and service
- Self-load test function — commissioning and on-site testing without costly temporary load banks, cabling and breakers.
- Automatic dust-removal function.
- Intelligent fan control and redundant construction.
- Wide input voltage and frequency range: high tolerance to mains fluctuation and longer battery life.
Communication and integration
- SNMP for remote monitoring and integration with supervisory systems.
- RS-485 and MODBUS RTU — communication with building and industrial automation.
- RS-232 for local and service connections.
- Programmable volt-free contact cards for event signalling.
The best batteries on the market
The life of an uninterruptible power system is set by the battery, not the electronics. That is why we use batteries with a EUROBAT design life of 10–12 years and above, plus our own lithium-ion solution.
EUROBAT 10–12 years (Long Life)
7.2–260 Ah
The proven standard for most installations: a predictable design life and a wide capacity range that lets the backup time be matched to the facility.
EUROBAT 12+ years (Very Long Life)
9–240 Ah
High Rate construction in a flame-retardant UL94 V-0 case — for facilities with elevated fire requirements and the longest expected service life.
Lithium-ion LFP system
40–100 Ah modules
Our own solution with LFP cells and a built-in integrated fire-suppression system. Up to 20 years of service life and over 5000 charge cycles, working with UPS units from 6 to 1200 kVA.
Battery condition is checked with an impedance tester during inspections — this finds a cell losing capacity before it fails during a real outage.
Where our UPS systems work
The common denominator across all these applications: a load that tolerates no break in supply, however brief.
- Server rooms and data centers
- Protection of servers, storage arrays and network equipment
- Hospitals and medical facilities
- Medical equipment and patient monitoring systems
- Offices and IT centres
- File servers, workstations, network devices
- Telecommunications
- Base stations and signal processing centres
- Industry and automation
- PLC controllers, SCADA systems, production lines
- Finance and banking
- Banking systems, ATMs, transaction centres
- Retail and services
- POS systems, ERP, monitoring
- Public buildings
- Alarm, access control and emergency lighting systems
Complete UPS support
One partner responsible for the system throughout its service life — from sizing to battery replacement.
Free consultation and sizing
Our engineers will match the UPS to what the facility actually needs. We analyse the load, the required backup time, environmental conditions and budget — including when the right answer is a smaller unit than expected.
Installation and commissioning
Complete delivery of the installation, without splitting responsibility between contractors.
- Electrical installation design
- Delivery and installation of equipment
- Commissioning and on-load testing
- Training for technical staff
Warranty and post-warranty service
Keeping the system ready throughout the life of the installation.
- Regular inspections and maintenance
- Battery diagnostics with an impedance tester
- Replacement of batteries and power modules
- Spare parts available from stock in Poland
- Service response within 24–48 hours
- Technical support by phone and remotely
Monitoring and management
Visibility of UPS operation without a visit to the plant room.
- SNMP cards for remote monitoring
- Integration with BMS and SCADA systems
- E-mail and SMS event notifications
- Event history and reports
Let's size the UPS for your facility
Tell us which loads have to survive an outage — we will size the power and backup time and prepare a quote.