Skip to content
Uninterruptible power

UPS systems

A UPS is not an expense — it is an investment in the safety of your data and the continuity of your business.

We supply professional UPS systems with the best batteries on the market. We specialise in on-line double-conversion units classified VFI-SS-111 — the highest protection category under IEC 62040-3, in which the load is isolated from mains disturbances and the transfer time is zero.

25+ years

of experience in uninterruptible power

~4000

completed installations

ISO 9001:2015

certified quality management system

A complete range from 1 kVA to 1200 kVA

From compact single-phase Tower and rack-mount units to modular 1.2 MW systems. One supplier, one service team, full system compatibility — the range covers both transformerless units and transformer-based units for harsh environmental and load conditions.

Single-phase Tower

1–3 kVA/kW

Compact protection for individual workstations and critical devices.

Single-phase Rack/Tower

1–10 kVA

Mounts in a 19" rack or stands alone — the same unit in either position.

Single-phase Rack/Tower Li-Ion

1–3 kVA

Internal lithium-ion battery: lower weight and longer service life.

Configurable Rack/Tower

10–40 kVA

Configurable phase arrangement 1/1, 3/1 and 3/3 — one unit for different supplies.

Configurable monobloc Tower

10–40 kVA

Compact free-standing enclosure for server rooms and plant rooms.

Monobloc

60–200 kVA

Powers entire critical-load switchboards from a single cabinet.

Modular

30–1200 kVA

Capacity grows module by module, with N+1 redundancy and module replacement without dropping the load.

Builds from our range

The same ON-LINE technology in several formats — from a Rack/Tower unit for a single server cabinet to free-standing cabinets and lithium-ion batteries in a separate enclosure.

Efficiency that shows up on the bill

All our UPS units have an output power factor of 1, so every kVA of rated power is fully usable — 100 kVA means a real 100 kW for the load, with no headroom lost to phase displacement.

1.0

output power factor

up to 97%

efficiency in online mode (three-phase)

up to 99%

efficiency in ECO mode

up to 0.99

input power factor

Four percentage points is a concrete sum

On a 100 kVA unit, a difference of four percentage points in efficiency means 4 kW less loss. In continuous operation that is roughly 35,000 kWh a year — energy that would otherwise turn into heat the room has to get rid of instead of reaching the load.

Calculated for continuous operation at full load (4 kW × 8760 h = 35,040 kWh). At lower loads the saving is proportionally smaller, but it grows by the cooling cost you no longer have to carry.

W-ECO mode reaches up to 98% efficiency, combining the savings of ECO mode with a faster return to online operation when mains quality deteriorates.

What sets our UPS units apart

Electronics and control

  • Dual DSP — a twin control and error-correction system.
  • Latest-generation IGBT transistors and three-level topology: low harmonics and high efficiency.
  • Full conformal coating on every PCB, protecting the electronics from the environment and corrosion.
  • Fault tracking management (FTM) — records the causes of events, not just their effects.
  • Intelligent battery charging that matches current to battery state and temperature.

Operation and reliability

  • High inverter overload capability — headroom for load start-ups.
  • Cold start: the UPS can be started from the batteries when there is no mains supply.
  • Power walk-in — the mains and the generator are re-loaded gradually after supply returns.
  • Intelligent generator mode, adapting UPS operation to work with a generator set.
  • Parallel operation of 2–8 units with a common battery bank.
  • Full rated power without derating up to 40 °C.

Operation and service

  • Self-load test function — commissioning and on-site testing without costly temporary load banks, cabling and breakers.
  • Automatic dust-removal function.
  • Intelligent fan control and redundant construction.
  • Wide input voltage and frequency range: high tolerance to mains fluctuation and longer battery life.

Communication and integration

  • SNMP for remote monitoring and integration with supervisory systems.
  • RS-485 and MODBUS RTU — communication with building and industrial automation.
  • RS-232 for local and service connections.
  • Programmable volt-free contact cards for event signalling.

The best batteries on the market

The life of an uninterruptible power system is set by the battery, not the electronics. That is why we use batteries with a EUROBAT design life of 10–12 years and above, plus our own lithium-ion solution.

EUROBAT 10–12 years (Long Life)

7.2–260 Ah

The proven standard for most installations: a predictable design life and a wide capacity range that lets the backup time be matched to the facility.

EUROBAT 12+ years (Very Long Life)

9–240 Ah

High Rate construction in a flame-retardant UL94 V-0 case — for facilities with elevated fire requirements and the longest expected service life.

Lithium-ion LFP system

40–100 Ah modules

Our own solution with LFP cells and a built-in integrated fire-suppression system. Up to 20 years of service life and over 5000 charge cycles, working with UPS units from 6 to 1200 kVA.

Battery condition is checked with an impedance tester during inspections — this finds a cell losing capacity before it fails during a real outage.

Where our UPS systems work

The common denominator across all these applications: a load that tolerates no break in supply, however brief.

Server rooms and data centers
Protection of servers, storage arrays and network equipment
Hospitals and medical facilities
Medical equipment and patient monitoring systems
Offices and IT centres
File servers, workstations, network devices
Telecommunications
Base stations and signal processing centres
Industry and automation
PLC controllers, SCADA systems, production lines
Finance and banking
Banking systems, ATMs, transaction centres
Retail and services
POS systems, ERP, monitoring
Public buildings
Alarm, access control and emergency lighting systems

Complete UPS support

One partner responsible for the system throughout its service life — from sizing to battery replacement.

01

Free consultation and sizing

Our engineers will match the UPS to what the facility actually needs. We analyse the load, the required backup time, environmental conditions and budget — including when the right answer is a smaller unit than expected.

02

Installation and commissioning

Complete delivery of the installation, without splitting responsibility between contractors.

  • Electrical installation design
  • Delivery and installation of equipment
  • Commissioning and on-load testing
  • Training for technical staff
03

Warranty and post-warranty service

Keeping the system ready throughout the life of the installation.

  • Regular inspections and maintenance
  • Battery diagnostics with an impedance tester
  • Replacement of batteries and power modules
  • Spare parts available from stock in Poland
  • Service response within 24–48 hours
  • Technical support by phone and remotely
04

Monitoring and management

Visibility of UPS operation without a visit to the plant room.

  • SNMP cards for remote monitoring
  • Integration with BMS and SCADA systems
  • E-mail and SMS event notifications
  • Event history and reports

Let's size the UPS for your facility

Tell us which loads have to survive an outage — we will size the power and backup time and prepare a quote.